Free Window & Door Replacement Estimate Template
A complete, line-item window and door estimate you can preview below — replacement units, sill pan and flashing, low-expansion foam, interior and exterior trim, disposal and labor — with a plain-language guide to egress sizing, safety glazing, tempered-glass locations and energy-code U-factors.
| Line item | Qty | Amount |
|---|---|---|
| Vinyl double-hung windows (Low-E, argon) | 10 | $5,400.00 |
| Basement egress window + well | 1 | $2,150.00 |
| Fiberglass entry door w/ hardware | 1 | $1,780.00 |
| Sill pans, flashing tape & sealant | 1 lot | $465.00 |
| Low-expansion foam & insulation | 1 lot | $180.00 |
| Interior & exterior trim / capping | 12 openings | $1,560.00 |
| Installation labor | 12 openings | $3,600.00 |
| Haul-away & disposal | 1 | $240.00 |
| Total | $15,375.00 | |
Payment schedule
How to measure and price windows & doors work
- Price per opening, not per square foot — each unit carries its own labor, trim and flashing cost.
- Separate insert (pocket) replacement from full-frame replacement; full-frame doubles the labor and adds exterior capping.
- Add lines for lead-safe practices on pre-1978 homes, for capping in aluminum coil, and for disposal.
Windows & Doors building-code guide
Three code items decide whether a window job passes: is it an egress opening, does the glass need to be tempered, and does it meet the energy code for your climate zone.
- Every sleeping room and basement with habitable space needs one egress opening
- Minimum net clear opening 5.7 sq ft (5.0 sq ft at grade floor), min height 24in, min width 20in
- Sill height max 44" above the finished floor; window wells need 9 sq ft area, 36" projection, and a ladder if deeper than 44"
- Tempered glass required in doors and in fixed panels within 24in of a door edge when the bottom edge is under 60in
- Required for glazing where the bottom edge is under 18", the top edge over 36", and the area exceeds 9 sq ft near a walking surface
- Always required in tub, shower and pool enclosures within 60in of the standing surface
- Window U-factor limits by climate zone — commonly 0.30–0.32 in zones 4–8 and SHGC 0.25 or lower in zones 1–3
- Keep the NFRC label on every unit until the inspector sees it; that label is your proof of compliance
- Replacing more than a set percentage of glazing area can trigger a whole-house energy compliance path in some jurisdictions
- A sloped sill pan or pan flashing is required at every window and door opening
- Sequence: sill pan → jamb flashing → head flashing lapped over the WRB, so water always sheds outward
- Insulate the shim space with low-expansion foam only — standard foam bows the jambs and binds the sash
Code quick reference — Windows & Doors
| Item | Requirement | Code reference |
|---|---|---|
| Egress opening | 5.7 sq ft clear, 24in min H, 20in min W | IRC R310.2.1 |
| Egress sill height | 44in max above the finished floor | IRC R310.2.2 |
| Safety glazing | Tempered near doors, tubs/showers, stairs, low glazing | IRC R308.4 |
| Fall protection | Window opening control where sill < 24in and drop > 72in | IRC R312.2 |
| Flashing | Sloped sill pan, jamb and head flashing over the WRB | IRC R703.4 |
| Garage/house door | 20-minute or 1-3/8in solid-core, self-closing | IRC R302.5.1 |
Drawings & details
Simplified section and plan views of the details inspectors look at most. Illustrative only — not to scale.
Adjust the values — the drawing below updates in real time.
- 1 · Head flashing over flange — Layer in the assembly, drawn top to bottom(0.06")
- 2 · Window unit + shims — square, level, plumb(0.50")
- 3 · Jamb flashing tape — Layer in the assembly, drawn top to bottom(0.06")
- 4 · Sloped sill pan — drains to exterior(0.50")
- Head flashing over flange: 0.06"
- Window unit + shims: 0.50"
- Jamb flashing tape: 0.06"
- Sloped sill pan: 0.50"
- Total assembly: 1.13" (1 2/16")
Adjust the values — the drawing below updates in real time.
- 1 · Front clearance — 5.7 sq ft clear opening · 24in H / 20in W min(5.69")
- 2 · Rear clearance — Sill 44in max above floor(44.00")
- 3 · Unit / fixture width — Egress window(60.00")
- 4 · Wall to wall — Total room dimension needed(6' 6 7/16")
- Front clearance: 5.69" · Rear clearance: 44.00"
- Unit / fixture width: 60.00"
- 5.7 sq ft clear opening · 24in H / 20in W min
Inspection-day checklistShow
- Rough opening square, plumb and 1/2in oversize for shims.
- Sill pan installed and sloped; bottom flange left un-taped to drain.
- Low-expansion foam only around jambs to avoid bowing.
- Tempered stamps visible in hazardous locations.
- Operation, locking and weatherstrip checked after trim.
Code references are based on the 2021 IRC and related model codes. Local amendments, state codes and manufacturer instructions can be stricter — always confirm with your local building department before starting work.
Common windows & doors estimating mistakes
- Quoting a basement window without checking whether it must meet egress — a well and ladder can add $2,000.
- Missing tempered-glass locations, which means reordering the unit at your cost.
- Measuring only one opening and assuming the rest match; always measure every opening in three places.
Export a branded, client-ready PDF or send a sign-from-phone link.
Your client reviews and signs the estimate from any device.
IRC egress sizing, tempered-glass locations, climate-zone U-factors and correct flashing sequence at every opening.
Windows & Doors estimate FAQ
What should a window replacement estimate include?
A window estimate should list each unit by type and size, sill pan and flashing, insulation, interior and exterior trim or capping, installation labor per opening, disposal, and any egress or tempered-glass upgrades.
What size window meets egress code?
IRC R310 requires a net clear opening of at least 5.7 square feet (5.0 at grade level), with a minimum height of 24 inches, minimum width of 20 inches, and a sill no higher than 44 inches above the floor.
When is tempered glass required?
Tempered glazing is required in doors, in panels near door edges, in large low glazing next to walking surfaces, and within 60 inches of a tub or shower standing surface, per IRC R308.4.
Turn this template into your estimate