Free Plumbing Estimate Template

A complete, line-item plumbing estimate you can preview below — supply rough-in, drain and vent piping, fixture sets, water heater, permit and licensed labor — plus a plain-language code checklist for fixture units, trap arms, venting and slope.

Estimate #PT-2026-044
Alvarez Residence — Bath Remodel & Repipe
9 fixtures · PEX repipe · 50 gal water heater · permit included
Sample
Line itemQtyAmount
Supply rough-in — 1/2" & 3/4" PEX with manifold9 fixtures$1,485.00
DWV drain & vent piping — 2" / 3" PVC112 ft$980.00
Fixture sets — toilets, lavatories, kitchen sink6$1,740.00
Tub / shower valve & trim2$620.00
50 gal gas water heater + connections & pan1$1,395.00
Labor — licensed plumber + apprentice34 hrs$2,890.00
Permit & inspection1$265.00
Total$9,375.00

Payment schedule

Deposit (on approval) (30%)$2,812.50
Rough-in inspection passed (40%)$3,750.00
Final — fixture set & final inspection (30%)$2,812.50

How to measure and price plumbing work

  • Count fixtures — most residential plumbing is priced per fixture rough-in plus per fixture set.
  • Add linear-foot piping for repipes and DWV runs, then the water heater or equipment as its own package.
  • Include concrete cutting, excavation, and drywall patching whenever pipes are behind or below finished surfaces.

Plumbing building-code guide

2021 IPC / UPC + IRC Part VII (P2601–P3201) — plumbing systems

Plumbing rough-in inspections are about slope, venting, trap arms, pipe support and testing. Get these right and the inspection is a formality.

DRAINAGE & SLOPE (IRC P3005 / IPC 704)
  • Horizontal drains 2-1/2in and smaller: min 1/4in per foot of fall; 3in–6in: min 1/8in per foot
  • Cleanouts required at each change of direction >45°, at the base of every stack, and max 100 ft apart
  • Minimum drain sizes: lavatory 1-1/4in, kitchen sink/shower 1-1/2in, water closet 3in
TRAPS & VENTS (IRC P3105 / P3201)
  • Every fixture needs a trap and a vent; trap seal 2in–4in; no S-traps or double trapping
  • Max trap arm length: 1-1/4in pipe = 5 ft, 1-1/2in = 6 ft, 2in = 8 ft, 3in = 12 ft
  • Vent terminals: min 6in above the roof, at least 10 ft from or 3 ft above any openable window
WATER SUPPLY (IRC P2903)
  • Static pressure must be between 40 and 80 psi — a pressure-reducing valve is required above 80 psi
  • Minimum flow pressure at fixtures: 8 psi most fixtures, 20 psi for a flushometer or tankless heater
  • Shut-off valves required at each fixture and on the main; anti-scald valves required at tubs and showers (max 120°F)
SUPPORT, TESTING & WATER HEATERS (P2605 / P2503 / P2803)
  • Pipe support: PEX every 32in horizontal, copper 1/2in every 6 ft, PVC drains every 4 ft and at each joint
  • DWV must hold a 10 ft water column test (or 5 psi air) for 15 minutes; water supply tested at working pressure
  • T&P relief valve discharge piped full-size to within 6in of the floor, with a drain pan under heaters in finished areas

Code quick referencePlumbing

ItemRequirementCode reference
Drain slope1/4 in per ft for 2-1/2in and smaller; 1/8in allowed on 3in+IRC P3005.3
Trap armVent within the maximum developed length; no S-trapsIRC P3105
CleanoutsAt base of stacks and each 100 ft of horizontal runIRC P3005.2
Water heater reliefFull-size T&P discharge to an approved locationIRC P2804
Test pressureWater 50 psi / DWV 10 ft head before close-inIRC P2503
Shower valvePressure-balancing or thermostatic, 120°F maxIRC P2708.4

Drawings & details

Simplified section and plan views of the details inspectors look at most. Illustrative only — not to scale.

Drain slope & venting
Fixture2 · 4.81"3 · 20'4 · 4.00"To stack / sewer
Clearances, spacing & part thickness

Adjust the values — the drawing below updates in real time.

Drawing legend
  • 1 · Sloped surface1/4 in per ft (min 1/8in on 3in+)(2%)
  • 2 · Total fallDrop from high point to low point(4.81")
  • 3 · RunFixture(20')
  • 4 · Slab / gutter thicknessTo stack / sewer(4.00")
Client presentation summary
  • Slope: 2% (4.81" over 20')
  • Slab / gutter thickness: 4.00"
  • 1/4 in per ft (min 1/8in on 3in+)
Every trap needs a vent within the maximum trap-arm length; no S-traps.
Water distribution
1 · Fixture supply + stop valve — 0.50"0.50"2 · PEX / copper branch — 0.50"sized for fixture units0.50"3 · Manifold or main — 0.50"pressure test before close-in0.50"4 · Water heater + T&P relief — 0.50"full-size discharge to outside0.50"2"Section view — top layer first · Total assembly: 2.00"
Clearances, spacing & part thickness

Adjust the values — the drawing below updates in real time.

Drawing legend
  • 1 · Fixture supply + stop valveLayer in the assembly, drawn top to bottom(0.50")
  • 2 · PEX / copper branchsized for fixture units(0.50")
  • 3 · Manifold or mainpressure test before close-in(0.50")
  • 4 · Water heater + T&P relieffull-size discharge to outside(0.50")
Client presentation summary
  • Fixture supply + stop valve: 0.50"
  • PEX / copper branch: 0.50"
  • Manifold or main: 0.50"
  • Water heater + T&P relief: 0.50"
  • Total assembly: 2.00" (2")
Support PEX at manufacturer intervals; protect pipe through framing with nail plates.
Inspection-day checklistShow
  • Rough-in pressure/head test held with a gauge during inspection.
  • Nail plates on every pipe passing through a stud or plate.
  • Vents extended through the roof with the correct clearance from openings.
  • Shower pan flood test held 24 hours before tiling.
  • Backflow protection on hose bibbs and irrigation connections.

Code references are based on the 2021 IRC and related model codes. Local amendments, state codes and manufacturer instructions can be stricter — always confirm with your local building department before starting work.

Common plumbing estimating mistakes

  • Quoting a repipe without allowing for wall and ceiling access holes and their repair.
  • Forgetting the expansion tank, pan, or T&P discharge line on a water heater swap.
  • Not checking incoming water pressure — an $80 PRV becomes a warranty claim if missed.
PDF & client share

Export a branded, client-ready PDF or send a sign-from-phone link.

Digital signature

Your client reviews and signs the estimate from any device.

Code-aware

IPC/UPC guidance for fixture units, trap arms, venting, slope and pipe support.

Plumbing estimate FAQ

What should a plumbing estimate include?

A plumbing estimate should list supply rough-in (PEX or copper), DWV drain and vent piping, each fixture set, the water heater and connections, valves and trim, the permit and inspection, licensed plumber labor hours, and a milestone payment schedule.

How do you price a plumbing estimate?

Most plumbing work is priced per fixture rough-in and set, plus material cost. Count the fixtures, apply a per-fixture labor and material rate, add the water heater or equipment, then add permit, inspection, and any excavation, concrete cutting or drywall patching.

What codes apply to residential plumbing?

Depending on the state, the IPC, UPC or IRC Part VII applies. The most-checked items are drain slope (1/4in per foot up to 2-1/2in pipe), trap arm length limits, vent termination, pipe support spacing and the required rough-in pressure test.