Free Insulation Estimate Template

A complete, line-item insulation estimate you can preview below — air sealing, attic blown-in cellulose to R-49, wall batts, rim-joist spray foam, baffles and attic hatch — with a plain-language guide to climate-zone R-values, ventilation baffles, ignition barriers and vapor retarders.

Estimate #IN-2026-168
Ramirez Residence — Attic & Envelope Upgrade
1,500 sf attic to R-49 · 620 sf walls · rim joist foam
Sample
Line itemQtyAmount
Air sealing — top plates, penetrations, can lights1 lot$980.00
Attic blown-in cellulose to R-491,500 sf$2,250.00
Ventilation baffles at eaves34$408.00
R-21 wall batts (open walls)620 sf$930.00
Rim joist closed-cell spray foam (2in)148 lf$1,036.00
Insulated & weatherstripped attic hatch1$285.00
Labor & site protection1 lot$1,150.00
Total$7,039.00

Payment schedule

Deposit (on approval) (30%)$2,111.70
Air sealing complete (30%)$2,111.70
Final — insulation installed & inspected (40%)$2,815.60

How to measure and price insulation work

  • Attic blow-in is priced per square foot at a target R-value; confirm the depth marker count required for inspection.
  • Batts are priced per square foot of cavity area; spray foam is priced per board foot (sq ft x inches of thickness).
  • Always list air sealing separately — it is labor, not material, and it is what makes the job perform.

Insulation building-code guide

2021 IECC / IRC Chapter 11 (N1102) · IRC R806 ventilation · R316 foam plastics

Insulation is inspected for R-value by assembly, for the air-sealing package that goes with it, and for the fire and ventilation details that make the assembly legal.

R-VALUE BY CLIMATE ZONE (IRC Table N1102.1.3)
  • Attic: R-30 in zone 1, R-38 in zones 2–3, R-49 in zones 4–5, R-60 in zones 6–8
  • Wood-frame walls: R-13 to R-20+5 depending on the zone; continuous exterior insulation counts toward the total
  • Floors over unconditioned space: R-13 to R-30; basement and crawl walls R-10/13 or better in colder zones
AIR SEALING (IRC N1102.4)
  • A visual air-barrier inspection or a blower-door test is required; typical limit is 3–5 ACH50 depending on the zone
  • Seal top plates, chases, plumbing and wiring penetrations, recessed lights (IC-rated, air-tight), and the attic hatch
  • Insulation without air sealing loses most of its real-world value — sell the two together
VENTILATION & BAFFLES (IRC R806)
  • Vented attics need 1 sq ft of net free vent area per 150 sq ft, or 1/300 with a balanced ridge/soffit split
  • Install baffles at every rafter bay to keep the soffit vent path open above the insulation
  • Unvented (conditioned) attics require air-impermeable insulation at the roof deck and follow R806.5 exactly
FOAM PLASTIC & CLEARANCES (IRC R316 / R302)
  • Spray foam and rigid foam need a thermal barrier (typically 1/2" gypsum) or an approved ignition barrier in attics and crawls
  • Keep insulation clear of chimneys, flues and non-IC recessed fixtures per the required clearance
  • Vapor retarder class and placement depend on the climate zone — the wrong side traps moisture in the wall

Code quick referenceInsulation

ItemRequirementCode reference
Ceiling R-valueR-49 to R-60 depending on climate zoneIECC Table R402.1.2
Wall R-valueR-13 to R-21 plus continuous insulation in cold zonesIECC Table R402.1.2
Air sealingContinuous air barrier; blower-door test requiredIECC R402.4
Attic bafflesMaintain soffit airflow at eavesIRC R806.3
Vapor retarderClass I/II on the interior in cold climatesIRC R702.7
Ignition barrierRequired over exposed foam in attics/crawlsIRC R316.5

Drawings & details

Simplified section and plan views of the details inspectors look at most. Illustrative only — not to scale.

Attic assembly
1 · Loose-fill / batt insulation — 60.00"R-49 to R-60 in most US zones60.00"2 · Air barrier / ceiling drywall — 0.06"3 · Baffles at eaves — 0.50"keep soffit vents open4 · Vented attic space — 0.50"1/300 with balanced venting5' 1 1/16"Section view — top layer first · Total assembly: 61.06"
Clearances, spacing & part thickness

Adjust the values — the drawing below updates in real time.

Drawing legend
  • 1 · Loose-fill / batt insulationR-49 to R-60 in most US zones(60.00")
  • 2 · Air barrier / ceiling drywallLayer in the assembly, drawn top to bottom(0.06")
  • 3 · Baffles at eaveskeep soffit vents open(0.50")
  • 4 · Vented attic space1/300 with balanced venting(0.50")
Client presentation summary
  • Loose-fill / batt insulation: 60.00"
  • Air barrier / ceiling drywall: 0.06"
  • Baffles at eaves: 0.50"
  • Vented attic space: 0.50"
  • Total assembly: 61.06" (5' 1 1/16")
Air-seal top plates, can lights and penetrations BEFORE insulating — air leaks beat R-value.
Clearances & ignition barrier
Recessed light / flue1 · 36.00"2 · 2.00"3 · 60.00"4 · 5' 6 12/16"
Clearances, spacing & part thickness

Adjust the values — the drawing below updates in real time.

Drawing legend
  • 1 · Front clearanceKeep insulation off non-IC fixtures(36.00")
  • 2 · Rear clearance2in from B-vent / masonry chimney(2.00")
  • 3 · Unit / fixture widthRecessed light / flue(60.00")
  • 4 · Wall to wallTotal room dimension needed(5' 6 12/16")
Client presentation summary
  • Front clearance: 36.00" · Rear clearance: 2.00"
  • Unit / fixture width: 60.00"
  • Keep insulation off non-IC fixtures
Inspection-day checklistShow
  • Air sealing done and inspected before insulation goes in.
  • Baffles at every rafter bay over the exterior wall.
  • Insulation depth markers installed in the attic.
  • IC-rated fixtures where insulation contacts can lights.
  • Blower-door result documented for the energy code.

Code references are based on the 2021 IRC and related model codes. Local amendments, state codes and manufacturer instructions can be stricter — always confirm with your local building department before starting work.

Common insulation estimating mistakes

  • Blowing attic insulation before air sealing, which buries the leaks you were paid to fix.
  • Forgetting baffles and the attic hatch, both common inspection failures.
  • Quoting spray foam by square foot instead of board foot, and losing money on thickness.
PDF & client share

Export a branded, client-ready PDF or send a sign-from-phone link.

Digital signature

Your client reviews and signs the estimate from any device.

Code-aware

IECC R-value tables by climate zone, blower-door air-sealing targets, attic ventilation baffles and foam ignition barriers.

Insulation estimate FAQ

What should an insulation estimate include?

An insulation estimate should list air sealing, the insulation type and target R-value by assembly, ventilation baffles, rim joist treatment, the attic hatch, labor, and site protection or cleanup.

How much attic insulation does code require?

The 2021 IECC requires roughly R-30 in climate zone 1, R-38 in zones 2–3, R-49 in zones 4–5 and R-60 in zones 6–8 for vented attics, along with a documented air-sealing package.

Does spray foam need a fire barrier?

Yes. IRC R316 requires foam plastic to be separated from the interior by a thermal barrier such as half-inch gypsum board, or protected by an approved ignition barrier in attics and crawl spaces.

Turn this template into your estimate